Ready to use disposables
Beside ready to use pre-filled disposables we offer also empty sterile vials with 4 electrodes to be used with our impedance analyzers.
The empty measuring cells can be filled with home made nutrient medie prepared from SY-LAB impedance media powders.
Ready to use pre-filled disposables have a shelflife between 6 and 10 months from manufacture and most of them can be stored between 2 and 25°C.
Advantages of Impedance disposables
Prefilled 4-Electrode cells M + E value registration
Prefilled 4 Electrode cells for M + E value registration (120 tests per box)
Ready to use impedance cells with 4 electrodes. This cells can be used for M- and E- value applications and are the cells of choice for the application of the BacTrac impedance splitting technology.
The use of 4 electrode cells M+E in µ-Trac is possible but not needed for the BioTrac applications. The BioTrac can be used more economically with 4- electrode cells for M-only registration instead.
Product list pre-filled 4 electrode cells
Cat. No. | Description |
---|---|
41-440014 | TMAC BiMedia 001B (4 electrodes) 9 ml |
41-440016 | TMAC BiMedia 001B+TLH (4 electrodes) 9ml |
41-440024 | TMAC BiMedia 002A (4 electrodes) 9 ml |
41-440011 | TMAC incl. Y+M, BiMedia 001C (4 electrodes) 9 ml |
41-440019 | TMAC incl. Y+M 001C + TLH (4 electrodes) 9 ml (for cosmetic applications) |
41-445154 | Yeasts & Moulds, direct method BiMedia 515A (4 electrodes) 9 ml |
41-441555 | E.coli BiMedia 155A 4 electrodes, 7.5 ml |
41-441554
| E.coli BiMedia 155A 4 electrodes, 9 ml |
41-442014 | Salmonella Bimedia 201C (4 electrodes) 9.9 ml |
41-446100 | B.cereus BiMedia 002A (4 electrodes) 9 ml |
41-443550 | S.aureus BiMedia 002A (4 electrodes) 9 ml |
41-430012 | Screw caps, white, sterile 40 pcs, |
Prefilled 4-Electrode cells, M-only
Prefilled 4 Electrode cells, M-only (120 tests per box)
This type of eady to use impedance cells with 4 electrodes is used for applications based on standard impedance (M-value) detection. These are the cells of choice for all the BioTrac applications but also for selected BacTrac applications.
Please refer to the application notes for making the proper choice.
Product list pre-filled 4 electrode cells, M-only
Cat. No. | Description |
---|---|
41-440013 | TMAC BiMedia 001B (4 electrodes) 9 ml |
41-441404 | Enterobacteriaceae BiMedia 140A+ (4 electrodes) 9 ml |
41-441407 | Enterobacteriaceae BiMedia 140B (4 electrodes) 9 ml for past. dairy products |
41-441456 | Enterobacteriaceae BiMedia 145A incl. Vancomycin (4 electrodes) 9 ml |
41-441604 | Coliforms BiMedia 160C (4 electrodes) 9 ml |
41-443304 | Enterococci BiMedia 330A (4 electrodes) 9 ml |
41-442054 | Salmonella BiMedia 205A (4 electrodes) 9,9 ml Selenite Cystein formulation |
41-430012 | Screw caps, white, sterile 40 pcs, |
Prefilled vials for indirect impedance
Pre-filled vials for indirect impedance
Ready to use inner vials for the use in indirect impedance (CO2 detection).
This vials must be used in combination with the 5-times re-useable outer vials for indirect impedance (41-440006) and screw caps to tightly close the outer impedance cell.
Product list pre-filled indirect impedance cells
Cat. No. | Description |
---|---|
41-415010 | Yeast & Mould BiMedia 501B, inner vial 5 ml |
41-415016 | Yeast & Mould BiMedia 501B + TLH, inner vial 5 ml |
Indirect Impedance (CO2) accessories
Indirect impedance vials
The indirect impedance cells are equipped with two short electrodes and packed in trays of 143 cells. These vials can be re-used up to 5 times with no need for sterilisation.
Outer vials need to be closed tightly with screw caps (caps with and without gaskets are available)
Inner vials are available ready to use and as sterile empty vials with flipcap to be filled by the user with sterile nutrient media for indirect impedance.
Product list indirect impedance
Cat. No. | Description |
---|---|
41-440006+ | Indirect Measuring cell, outer vial for indirect method |
41-410004+ | Inner vial with flip cap, empty, sterile, 7 ml max filling volume, 400 pcs/box |
41-430024 | Screw cap with gasket, non sterile 143 pcs/ pack |
41-430012 | Screw cap without gasket, sterile, 40 pcs/ bag |
Empty vials direct impedance method
Sterile, empty vials for Impedance
The vials are available as M-value only version as well as combined M & E-value version. For all BioTrac applications the M-only version will be appropriate. For BacTrac both versions can be used. The advantage offered by the impedance splitting technology can only be used in combination with M&E-value type cells.
The later are therefore the most versatile cells whenever you don´t precisely know what application will be the most appropriate.
Cells come along equipped with screw caps.
Please note that impedance technology will need special nutrient media adapted for the needs of impedance. Standard microbiological nutrient media can lead to erroneous results.
Product list empty impedance vials
Cat. No. | Description |
---|---|
41-440003 | Measuring cell, 4 electrodes, M-value only, sterile with cap, 20 ml volume, 400 pcs./ box |
41-440004 | Measuring cell, 4 electrodes, M & E-value, sterile with cap, 20 ml volume, 400 pcs./ box |